New DV3400

Auto Memory Compression for Maximum Sampling

SALES:
972-272-9392
FAX:
972-494-5814
EMAIL:
»Sales
»Support
»IT Department

TechTools products also available at:
United States Canada Japan
DigiView™ Hardware Specifications

Additional DigiView Specs:

  DV1-100 DV3400
Power Source USB External
Idle power <.5 Watt 2.5 Watt
Active Power < 2.5W < 7 Watt
Sample Rate 100 MHz(10ns) 200 Mhz(5ns)
400 MHz(2.5ns)
Channels 18 18 or 36
Sample Count Varies with data due to real-time compression Varies with data due to real-time compression
Samples @ 100 Mhz Min: 128K (x18) @ 10ns = 1.3 ms
Max: 2^35 (34 Billion) @ 10ns = 5.7 minutes
N/A
Samples @ 200 Mhz N/A Min: 512K (x36) @ 5ns = 2.6 ms
Max: 2^52 (4.5 x 10^15) @ 5ns = 260 Days
Samples @ 400 Mhz N/A Min: 1M (x18) @ 2.5ns = 2.6 ms
Max: 2^53 (9 x 10^15) @ 2.5ns
= 260 Days
Raw Memory 4.5 Mbit 18 Mbit
Trigger position Auto or 50% Selectable (0-100%)
Trigger Sequencers 0 Configurable:
1@16 stages
OR 4@4 stages
OR 2@8 stages
OR 1@8 and 2@4 stages
OR 1@12 and 1@4 stages
Trigger Match Circuits 1 Pattern (18 bit AND: 1, 0, X)
1 Edge detect (18 bit OR: rising, falling, either)
8 Universal:
Each can be configured as:
- Edge Detect (36 bit OR: rising, falling, either)
- Patterns (36 bit AND: 0, 1, X)
- Stable (36 bit)
- > (36 bit RANGE)
- >= (36 bit RANGE)
- < (36 bit RANGE)
- <= (36 bit RANGE)
- = (36 bit RANGE)
- <> (36 bit RANGE)
Match Duration No Yes
- 1 per match circuit
- up to 1M samples each
Trigger Pass Count No Yes (up to 1 Million per Sequencer stage)
Trigger Output Sources Edge detect
OR Pattern detect
OR (Edge detect AND Pattern detect)
Seq 1
OR Seq 2
OR Seq 3
OR Seq4
OR (8 input sum-of-8 input products of all 8 match circuits)
External Trigger Output No Yes, BNC connector
Threshold Circuits 1 2 (1 for for each group of 18 channels)
Threshold Range fixed at 1.6V Adjustable (-6V to +6V)
Threshold Accuracy +- 100mv +- 250mv
Maximum voltage (Continuous, all channels) +10/-5V +-50 Volts
Impedance >100KOhm series, <10pf to ground (0-5V)
>1KOhm series, <10pf to ground (<0, >5V)
50KOhms, < 3pf
Anti-static protection Yes Yes
Ground current Protection (ground lead to +- voltage) No Yes, +-12 Volts
Size (LxWxH) 4.1" x 2.6" x .9" 5.0" x 4.25" x 1.40"